Calculate the current that will fuse a PCB trace using Onderdonk's equation. Includes etch-factor trapezoid correction, time-to-fuse at your operating current, and safety margin.

Onderdonk equation, adiabatic · trapezoidal etched cross-sectionAPI slug fusing-current

Sign in to saveSave

Inputs

Example
Width at the base of the trace, where it meets the laminate

20 µm or more

5 µm or more

1 ms or more

−55 to +150°C

Etch depth divided by lateral undercut per side (IPC-T-50). A larger number means straighter sidewalls; enter 0 for perfectly vertical walls

0 to 5

Optional — used to report time-to-fuse and safety margin

0 A or more

Results

Live

Fusing Current 5.053 A

Fusing CurrentIfuse
5.053A
Time to Fuse at Operating Currenttfuse
1.021s
Margin to FusingIfuse/I_op
1.011×FAIL
Cross-Sectional AreaA
27.13sq mil
Effective (Mean) WidthWeff
500µm
  • Only 1.01× margin to fusing — this is a survival limit, not a continuous rating. Size continuous current with IPC-2152 instead

Fusing Current against Trace Width (bottom)

495 µm maxOperating current 5 A0102030405060100 µm1 mmA

Drag the operating point or type a value.

Formula

I. M. Onderdonk, as published in E. R. Stauffacher, "Short-time Current Carrying Capacity of Copper Wire", General Electric Review, 1928; IPC-2152 Appendix A
I=Alog⁡10 ⁣[Tm−Ta234+Ta+1]33 SI = A\sqrt{\frac{\log_{10}\!\left[\frac{T_m - T_a}{234 + T_a} + 1\right]}{33\,S}}
SymbolQuantityYour value
IFusing current (A)—
ACross-sectional area (circular mils)27.13 sq mil
SFault duration (s)1 s
TmCopper melting point, 1083 (°C)—
TaAmbient temperature (°C)25 °C
With your inputs
I_fuse = A × √(log₁₀((1083 − 25 °C) / (234 + 25 °C) + 1) / (33 × 1 s)), A = mean width × thickness in circular mils, from 500 µm, 35 µm and etch factor 05.053 A
t_fuse = (A / 5 A)² × log₁₀((1083 − 25 °C) / (234 + 25 °C) + 1) / 331.021 s
k = I_fuse / 5 A1.011 ×

Assumptions

6 items
  1. 01Onderdonk's equation, I = A·√(log10[(T_m − T_a)/(234 + T_a) + 1] / (33·S)), with A in circular mils and S in seconds.
  2. 02Adiabatic heating: all I²R heat stays in the copper and none flows into the laminate or planes, so the result is a lower bound, meaningful for short events up to about 1.5 s.
  3. 03The trace fails when it reaches copper's melting point, 1083 °C, starting from the ambient temperature.
  4. 04A constant current for the whole duration, a rectangular pulse rather than a decaying fault.
  5. 05The cross-section is a rectangle, or a trapezoid narrowed by t/EF on each side when an etch factor is entered; plating variation is ignored.
  6. 06Bulk copper properties: the 234 °C inferred-zero-resistance temperature and the constant 33 fold in copper's resistivity, density and specific heat.

Worked example

0.5 mm, 1 oz trace with a 5 A, 1 s fault

A 0.5 mm wide, 1 oz (35 µm) trace with straight sidewalls at 25 °C ambient could carry a 5 A short-circuit current for up to 1 s before the upstream protection clears.

StepExpressionResult
Cross-section(0.5 / 0.0254) × (0.035 / 0.0254)27.13 sq mil
In circular mils27.13 × 4/π34.54 cmil
Temperature termlog10((1 083 − 25) / (234 + 25) + 1)0.7063
Fusing current in 1 s34.54 × √(0.7063 / (33 × 1))5.053 A
Time to fuse at 5 A(34.54 / 5)² × 0.7063 / 331.021 s
Margin5.053 / 51.011 ×

How it works

There are two completely different questions about how much current a trace can carry, and confusing them destroys hardware. IPC-2152 answers how much current can this trace carry forever without getting too hot. Onderdonk's equation answers how much current will melt this trace in a given time. The second number is far larger, and it is a destruction limit, not a rating.

Onderdonk assumed the fault is fast enough that no heat escapes the conductor — every joule of I2RI^2R goes into raising the copper's own temperature until it reaches the melting point. Integrating the temperature-dependent resistivity of copper across that adiabatic rise gives:

I=Alog⁡10 ⁣[Tm−Ta234+Ta+1]33 SI = A\sqrt{\frac{\log_{10}\!\left[\frac{T_m - T_a}{234 + T_a} + 1\right]}{33\,S}}

with AA in circular mils, SS in seconds, and temperatures in °C. The 234 is copper's inferred zero-resistance temperature; the 33 collects its density, specific heat, and resistivity for that unit system. At 25 °C ambient and one second, the whole square-root term evaluates to about 0.1463 A per circular mil — the same figure IEEE Std 80 uses for copper grounding conductors.

The inverse-square-root scaling

Fusing current scales as the inverse square root of duration. A trace that survives 10 A for one second survives about 32 A for ten milliseconds. That is why a short-circuit event and a slow overload need entirely different analyses.

Etch factor

Etched traces are not rectangular. The etchant attacks sideways as well as down, leaving a trapezoid narrower at the top than at the base. With a sidewall slope expressed as vertical rise per horizontal run, each side loses t/EFt/EF of width, and the cross-section uses the mean of the top and bottom widths. On 2 oz copper with a 1:1 slope, that removes a meaningful fraction of the conductor.

Where the model stops being conservative

Beyond about 1.5 s, the adiabatic assumption breaks down. A trace is bonded to laminate and often adjacent to copper planes, all of which absorb heat, so the real fusing current at long durations is higher than Onderdonk predicts. Brooks and Adam measured PCB traces taking 1.5 to 6 times longer to fuse than the equation predicts, which corresponds to surviving roughly 1.2 to 2.5 times more current. The error is always in the safe direction, but treat long-duration results as a lower bound and measure if the design depends on it.

Practical tips

  • Aim for at least a four times margin between the fusing current and the worst-case fault current the protection will allow.
  • Get the actual clearing time from your fuse, breaker, or current-limit circuit — the duration drives the answer more strongly than anything else.
  • Include the etch factor for 2 oz copper and heavier, where the sidewall slope removes a real fraction of the cross-section.
  • Prefer a real fuse over a fuse trace anywhere safety, repairability, or reproducibility matters.
  • Check the continuous rating with IPC-2152 and the fault rating with Onderdonk. Both must pass; they are different failures.
  • Remember that a hotter ambient lowers the fusing current, so run the calculation at the maximum internal temperature of the enclosure, not at room temperature.

Common mistakes

  • Using the fusing current as a continuous rating. It is the current that destroys the trace, typically three to four times the IPC-2152 continuous figure. Size normal operating current with IPC-2152 instead.
  • Ignoring the fault duration. Fusing current scales as one over the square root of time, so the same trace tolerates three times more current for a tenth of the duration.
  • Applying the adiabatic model to slow overloads. Past about 1.5 s the board absorbs significant heat and the equation becomes pessimistic by a factor of 1.2 to 2.5 — useful as a lower bound, not as a prediction.
  • Designing a deliberate fuse trace without accounting for etch tolerance. Width, copper weight, and etch factor all vary, so the actual fusing point can move by tens of percent.
  • Forgetting that a blown fuse trace vents molten copper onto the board and often damages the laminate and neighbouring nets.

Frequently asked questions

5 questions
What is Onderdonk's equation?

An adiabatic model for the current that melts a copper conductor in a given time. It assumes no heat leaves the conductor, so all resistive heating goes into raising its own temperature to the melting point. It is the same relation IEEE Std 80 uses for short-time ratings of grounding conductors.

Can I use this to size a trace for normal current?

No. Onderdonk gives a destruction limit, not a rating. Continuous current is set by temperature rise, which is what IPC-2152 addresses. The two numbers commonly differ by a factor of three or four.

Why does duration matter so much?

Because the energy delivered scales with current squared times time, the fusing current scales as one over the square root of duration. Ten times shorter means about 3.2 times more current tolerated.

Is a fuse trace a good design choice?

Occasionally, in cost-sensitive consumer products. The drawbacks are real though: poor tolerance because width, copper weight, and etch all vary; molten copper deposited on the board when it blows; and no way to reset or service it. Use a real fuse where any of that matters.

How accurate is the result?

Good for short faults, conservative for long ones. Below about 1.5 s the adiabatic assumption holds well, and the coefficient agrees with IEEE Std 80's copper short-time withstand figure to under one percent. Beyond that, the laminate and adjacent copper absorb heat the model ignores: Brooks and Adam measured real traces taking 1.5 to 6 times longer to fuse, so they survive roughly 1.2 to 2.5 times more current than predicted. The error is always in the safe direction.