Coplanar Waveguide Calculator (CPW & GCPW)
Calculate coplanar waveguide impedance for CPW and grounded CPW (GCPW/CBCPW). Get Z₀, effective dielectric constant, propagation delay, and the gap width for 50 Ω.
Simons conformal-mapping CPW and GCPW · copper-thickness correctionAPI slug coplanar-waveguide
Formula
R. N. Simons, "Coplanar Waveguide Circuits, Components and Systems", Wiley 2001, ch. 2 (zero-thickness line); copper thickness fitted to rftools.io’s field solver (impedance-field-solver)
| Symbol | Quantity | Your value |
|---|---|---|
| Z₀ | Characteristic impedance (Ω) | 46.9 Ω |
| W | Centre conductor width (mm) | 1 mm |
| G | Gap to coplanar ground (mm) | 300 µm |
| h | Substrate height (mm) | 508 µm |
| K(k) | Complete elliptic integral of the first kind | — |
| εreff | Effective dielectric constant | 2.484 |
| εeff,₀ | Effective dielectric constant of the zero-thickness line, from the conformal map | — |
| C₀ | Capacitance of the zero-thickness line in air, normalised to ε₀ | — |
| ΔC | Sidewall capacitance the copper adds across both gaps, normalised to ε₀; α 1.021, β 0.5255, A 0.1248 and κ 0.01712 fitted to rftools.io’s field solver | — |
| t | Copper thickness (mm) | 35 µm |
| η₀ | Impedance of free space, µ₀·c = 376.730 Ω (Ω) | — |
Assumptions
6 items
- 01Quasi-static conformal mapping (Simons): Z₀ and εeff are low-frequency values with no dispersion or loss; the frequency sets only λg = c/(f·√εeff), and the 1 GHz wavelength is that λg at 1 GHz.
- 02Grounded CPW: εeff₀ = 1 + q(εr − 1) with q = R(k₁)/(R(k₀) + R(k₁)), R(k) = K(k)/K(k′), k₀ = W/(W + 2G) and k₁ = tanh(πW/4h)/tanh(π(W + 2G)/4h), and Z₀ = η₀/(√εeff·(2[R(k₀) + R(k₁)] + ΔC)). The coplanar grounds and the backing plane are one equipotential, and the parallel-plate mode is not modelled.
- 03Ungrounded CPW: a substrate of height h with air below it, εeff₀ = 1 + (εr − 1)/2·R(k₂)/R(k₀) with k₂ built from sinh terms, and Z₀ = η₀/(√εeff·(4R(k₀) + ΔC)).
- 04Copper thickness adds sidewall capacitance across each gap, ΔC = 2(t/G)[α + β·ln(1 + A·G/t)] in units of ε₀, mostly in air (a share κ in the substrate), which lowers both Z₀ and εeff: εeff = (εeff₀·C₀ + ΔC·(1 + κ(εr − 1)))/(C₀ + ΔC), with α, β, A and κ fitted to rftools.io’s field solver over t/G 0.05–0.8 (grounded Z₀ within 1.3 % for G up to h/2, 5 % up to G = h); the coplanar grounds are infinitely wide and there is no soldermask.
- 05Each elliptic integral K is taken from its exact complementary modulus, never from √(1 − k²), which cancels once W/h exceeds about 24, so grounded CPW keeps a finite Z₀ for a strip wide against its substrate.
- 06The 50 Ω gap is a 60-step bisection over 0.01–10 mm at the entered width; synthesis solves the gap or the centre width numerically within its range, and the material picker sets εr to the laminate’s design Dk.
Worked example
50 Ω grounded CPW on 0.254 mm RO4350B
A 10 GHz feed uses grounded CPW on 0.254 mm (10 mil) RO4350B, design Dk 3.66, with a 0.5 mm centre conductor and 35 µm copper. Solve the gap for 50 Ω, then read εeff and the quarter-wave length at 10 GHz.
| Step | Expression | Result |
|---|---|---|
| Gap for 50 Ω (solved) | Z₀(G) = 50 Ω; W = 0.5 mm, h = 0.254 mm | 319.6 µm |
| Coplanar modulus k₀ | 0.5 / (0.5 + 2 × 0.319611) | 0.4389 |
| Modulus with the backing plane, k₁ | tanh(π × 0.5 / (4 × 0.254)) / tanh(π × (0.5 + 2 × 0.319611) / (4 × 0.254)) | 0.9147 |
| R(k₀) = K(k₀)/K(k₀′) | K(0.4389) / K(√(1 − 0.4389²)) | 0.7281 |
| R(k₁) = K(k₁)/K(k₁′) | K(0.9147) / K(√(1 − 0.9147²)) | 1.4315 |
| Effective permittivity, zero thickness | 1 + 1.4315 / (0.7281 + 1.4315) × (3.66 − 1) | 2.763 |
| Sidewall capacitance of the copper, ΔC/ε₀ | 2 × 0.035 / 0.319611 × (1.021 + 0.5255 × ln(1 + 0.1248 × 0.319611 / 0.035)) | 0.3112 |
| Effective permittivity with the copper sidewalls | (2.763 × 2 × (0.7281 + 1.4315) + 0.3112 × (1 + 0.01712 × (3.66 − 1))) / (2 × (0.7281 + 1.4315) + 0.3112) | 2.648 |
| Characteristic impedance | 376.730 / (√2.648 × (2 × (0.7281 + 1.4315) + 0.3112)) | 50 Ω |
| Quarter wave at 10 GHz | 299.792458 / (10 × √2.648) / 4 | 4.606 mm |
How it works
Coplanar waveguide (CPW) puts the signal conductor and its return grounds on the same copper layer, separated by two narrow gaps. That single change fixes several problems microstrip has at high frequency: the return current sits micrometres away instead of a substrate thickness away, the fields stay tightly bound to the gaps, and impedance stops depending on how thick the laminate happens to be.
The closed-form solution comes from conformal mapping. Transforming the cross-section turns the awkward three-conductor geometry into a parallel-plate capacitor, and the whole impedance falls out of one ratio of complete elliptic integrals:
where is the centre conductor width, is the gap to each coplanar ground, and . Notice what is missing: substrate height appears nowhere. For an ideal CPW on an infinitely thick substrate, impedance depends only on the ratio — scale the whole cross-section up or down and does not move.
Grounded CPW
In practice nobody builds on an infinitely thick substrate, and most designs add a ground plane on the far side to carry heat and provide a solid reference for the rest of the board. That is grounded CPW, also called GCPW or conductor-backed CPW. The backing plane pulls some field down into the substrate, which raises the effective permittivity and lowers impedance:
with . As the substrate gets thicker, , , and the expression collapses back to — the ungrounded CPW answer. That limit is a useful sanity check on any CPW tool.
Copper thickness matters twice
Finite metal thickness is not a second-order detail in CPW. The sidewalls widen the strip and narrow the gap, which lowers — that much is standard. Less often modelled is what it does to : the strip sidewall faces the ground sidewall across the gap, above the substrate surface, so that added capacitance is in air. It raises the air and substrate capacitances by the same absolute amount and therefore pulls down.
The effect is large. At 1 oz copper on a 0.3 mm gap it is worth about 3.5%, and at 2 oz on a 0.15 mm gap 10–12%. A zero-thickness formula misses all of it, and the error propagates straight into propagation delay and guided wavelength.
The regime that matters
Grounded CPW only behaves like CPW while the coplanar grounds dominate. Once the gap grows much larger than the substrate height, most field lines terminate on the backing plane instead, and the structure quietly turns into microstrip with some useless copper either side. Keep the gap comparable to or smaller than the substrate height to stay in the CPW regime.
The other practical requirement is stitching. The coplanar grounds and the backing plane form a parallel-plate cavity, and if they are only connected at the board edges that cavity will resonate somewhere in band. Rows of vias down both sides of the line short the two grounds together and push the cavity modes above the operating frequency.
Practical tips
- Keep the width-to-gap ratio constant through every taper, bend, and pad transition — that is what preserves impedance, not the absolute dimensions.
- Grounded CPW is usually the better launch structure at a connector, because the coplanar grounds line up naturally with the connector's outer contacts.
- Use the widest centre conductor your gap tolerance allows. Conductor loss falls with width, and etch tolerance becomes a smaller fraction of both the width and the gap.
- Space stitching vias at one twentieth of a wavelength or closer at the highest frequency of interest, and tighten the spacing near discontinuities.
- On thin substrates check whether grounded CPW is buying you anything. Below about 0.2 mm the backing plane dominates regardless of gap, and plain microstrip is simpler to fabricate.
- Watch surface roughness on low-loss laminates. CPW concentrates current at the gap edges, so edge roughness costs more than it does in microstrip.
Common mistakes
- Letting the gap grow much wider than the substrate height on a grounded CPW. The backing plane then dominates and the line is really microstrip — the CPW formula will disagree with measurement by tens of percent.
- Omitting stitching vias between the coplanar grounds and the backing plane. The two form a parallel-plate cavity that resonates in band and shows up as sharp, unexplained suck-outs in S21.
- Assuming impedance scales with substrate thickness the way it does for microstrip. For ungrounded CPW it barely depends on thickness at all — only the width-to-gap ratio matters.
- Ignoring copper thickness. At 1 oz on a 0.15 mm gap the metal is a quarter of the gap width, and neglecting the thickness correction overestimates impedance by several percent.
- Necking the centre conductor down without narrowing the gap proportionally. Impedance is set by the ratio, so any taper has to keep width and gap in step or it becomes an impedance discontinuity.
Frequently asked questions
5 questions
What is the difference between CPW and grounded CPW?
CPW has ground only on the signal layer, either side of the trace. Grounded CPW (GCPW or CBCPW) adds a plane on the far side of the substrate. The backing plane lowers impedance, raises effective permittivity, and gives a thermal and mechanical reference — but it also introduces a parallel-plate mode that must be suppressed with stitching vias.
Why does CPW impedance barely change with substrate thickness?
Because the return path is the coplanar ground beside the trace, not a plane underneath it. The field is set by the width-to-gap ratio, so on a thick substrate you can scale the whole cross-section and keep the same impedance. That is the opposite of microstrip, where thickness is the dominant variable.
How close together do stitching vias need to be?
One twentieth of a wavelength at the highest frequency of interest is the usual rule, tightening near connector launches and other discontinuities. The vias short the coplanar grounds to the backing plane and push the parallel-plate cavity resonance above the operating band.
When should I choose CPW over microstrip?
Above roughly 10 GHz, on thick substrates where a 50 ohm microstrip would need an impractically wide trace, and anywhere you want easy shunt component mounting — a CPW gives you ground right next to the signal, so shunt parts have almost no via inductance.
Does copper thickness matter for CPW?
More than it does for microstrip, and in two separate ways. The metal widens the strip and narrows the gap, which lowers impedance. Separately, the sidewall-to-sidewall capacitance sits in air above the substrate and pulls the effective permittivity down — about 3.5% at 1 oz on a 0.3 mm gap, over 13% at 2 oz on a 0.15 mm gap. The second effect is the one most calculators omit, and it feeds straight into propagation delay and guided wavelength.
References
Coplanar Waveguide Circuits, Components and Systems, ch. 2 · Transmission Line Design Handbook, §3.3 (coplanar lines) · Handbook of Mathematical Functions, ch. 17 (elliptic integrals)
- Coplanar Waveguide Circuits, Components and Systems, ch. 2 — R. N. Simons, Wiley 2001
- Transmission Line Design Handbook, §3.3 (coplanar lines) — B. C. Wadell, Artech House 1991
- Handbook of Mathematical Functions, ch. 17 (elliptic integrals) — Abramowitz & Stegun, NBS 1964
Complete elliptic integrals are evaluated by the arithmetic-geometric mean, which converges quadratically to double precision. The grounded-CPW branch is checked against its own limit: as substrate height grows the result converges to the ungrounded CPW value, with εr_eff → (1 + εr)/2. Copper thickness enters as sidewall capacitance across each gap, mostly in air, which lowers both Z₀ and εr_eff; its four constants are fitted to rftools.io’s field solver, whose accuracy record holds it to exact and published solutions. On a separate grid of solver cases the fit did not see: grounded CPW Z₀ within 1.3 % for gaps up to half the substrate height (5 % up to the full height) and εr_eff within 0.6 %; ungrounded CPW Z₀ within 1.5 % and εr_eff within 1.2 %. The ungrounded zero-thickness map itself reads εr_eff up to about 2.5 % low on a wide strip (2.4 % at the defaults).
Shop Components
As an Amazon Associate we earn from qualifying purchases.