PCB Copper Weight Reference
Copper weight (oz/ft²) to thickness conversion table with current carrying capacity for PCB trace design.
Conversion Formula
Weight to Thickness
1 oz/ft² = 35 μm = 1.37795 mil
General Formula
thickness (μm) = weight (oz) × 35
Copper Weight Specifications
| Weight | Thickness (μm) | Thickness (mil) | Thickness (mm) | Current @ 1mm* |
|---|---|---|---|---|
| 0.5 oz/ft² | 17.5 | 0.689 | 0.0175 | 1.2 A |
| 1 oz/ft² | 35 | 1.378 | 0.0350 | 2 A |
| 2 oz/ft² | 70 | 2.756 | 0.0700 | 3.5 A |
| 3 oz/ft² | 105 | 4.134 | 0.1050 | 4.8 A |
| 4 oz/ft² | 140 | 5.512 | 0.1400 | 6 A |
| 6 oz/ft² | 210 | 8.268 | 0.2100 | 8.2 A |
* Current capacity for 1mm trace width, external layer, 10°C temperature rise (IPC-2221)
Current Carrying Capacity (IPC-2221)
External layer, 10°C temperature rise above ambient. Internal layers carry approximately 50% of these values.
| Copper Weight | 1mm Trace | 2mm Trace | 3mm Trace |
|---|---|---|---|
| 0.5 oz/ft² | 1.2 A | 1.9 A | 2.5 A |
| 1 oz/ft² | 2 A | 3.2 A | 4.2 A |
| 2 oz/ft² | 3.5 A | 5.6 A | 7.4 A |
| 3 oz/ft² | 4.8 A | 7.7 A | 10.2 A |
| 4 oz/ft² | 6 A | 9.6 A | 12.7 A |
| 6 oz/ft² | 8.2 A | 13.1 A | 17.4 A |
Applications by Copper Weight
- →Fine-pitch BGA routing
- →High-density interconnect (HDI) boards
- →Smartphone and tablet PCBs
- →Inner layers in multilayer boards
Half-ounce copper is standard for HDI and fine-pitch designs. Lower current capacity limits use in power applications. Often paired with 1 oz outer layers.
- →General-purpose digital circuits
- →Consumer electronics
- →Signal routing layers
- →Standard commercial PCBs
Most common copper weight for general PCB fabrication. Good balance of current capacity, cost, and manufacturability. Standard baseline for IPC-2221 calculations.
- →Power distribution layers
- →Motor drivers
- →LED lighting boards
- →Automotive electronics
- →Industrial control systems
Double the current capacity of 1 oz copper. Common choice for power planes and high-current traces. Increases board cost by ~20-30%. May require adjusted trace/space rules.
- →High-power DC-DC converters
- →Battery management systems (BMS)
- →EV/HEV power electronics
- →Welding equipment
Heavy copper for demanding power applications. Requires special fabrication capabilities. Minimum trace/space typically 8-10 mil. Often combined with thinner signal layers.
- →Power supply boards
- →Busbar replacement
- →High-current motor controllers
- →Renewable energy inverters
Heavy copper requiring specialty PCB fabrication. Not all fabs support 4 oz+. Expect longer lead times and higher costs. May need edge plating for thermal relief.
- →Extreme power applications
- →Planar transformers
- →High-current busbars on PCB
- →Power conversion equipment
Ultra-heavy copper for extreme power requirements. Very few fabs can process 6 oz+. Often used with embedded busbars or coin insertion for thermal management.
Related Calculators
Trace Width
Calculate minimum PCB trace width for current capacity per IPC-2221 and IPC-2152. Get resistance, voltage drop, and power dissipation. Free, instant results.
Trace Resistance
Calculate PCB copper trace DC resistance from width, length, thickness, and temperature. Get sheet resistance and temp coefficient. Free, instant results.
Via Calculator
Calculate PCB via impedance, capacitance, inductance, and current capacity. Get aspect ratio and DFM warnings for through-hole and blind vias. Free, instant results.
Controlled Z
Calculate characteristic impedance for surface microstrip, embedded microstrip, and stripline PCB traces. Get Z0, effective Er, and target trace width. Free, instant results.