Minimum Conductor Spacing Calculator
Determine minimum electrical clearance between conductors per IPC-2221B Table 6.1 based on voltage and conductor condition.
IPC-2221B Table 6-1, a step per voltage band · B3 above 3,050 mAPI slug minimum-conductor-spacing
0 V to 1 kV
0 m to 30 km
10 µm to 50 mm
Conductor Spacing
PASS75 % of the B2 External, uncoated limit, 0.6 mm.
IPC-2221B Table 6-1, B2 (external conductors, uncoated, sea level to 3,050 m), 31–50 V
- Minimum Spacing
- 23.62mil
- Altitude Derating Factor
- 1×
- B1 (Internal)
- 100µm
- B2 (External Uncoated, to 3,050 m)
- 0.6mm
- B3 (External Uncoated, above 3,050 m)
- 0.6mm
- B4 (Polymer Coated)
- 130µm
All limits
| Standard | Limit rule | Limit | Your value | Minimum conductor spacing | Status |
|---|---|---|---|---|---|
| B1 Internal | 0.1 mm | 0.1 mm | 12.5 % | 100 µm | PASS |
| B2 External, uncoated | 0.6 mm | 0.6 mm | 75 % | 600 µm | PASS |
| B4 Polymer coated | 0.13 mm | 0.13 mm | 16.3 % | 130 µm | PASS |
| A5 Conformal coated | 0.13 mm | 0.13 mm | 16.3 % | 130 µm | PASS |
| A6 Leads, uncoated | 0.4 mm | 0.4 mm | 50 % | 400 µm | PASS |
| A7 Leads, coated | 0.13 mm | 0.13 mm | 16.3 % | 130 µm | PASS |
Sources: IPC-2221B, Generic Standard on Printed Board Design (November 2012), Table 6-1 Electrical Conductor Spacing and §6.3 (above 500 V), column B1: internal conductors; IPC-2221B (November 2012), Table 6-1, columns B2 (external conductors, uncoated, sea level to 3,050 m) and B3 (over 3,050 m); IPC-2221B (November 2012), Table 6-1, column B4: external conductors with permanent polymer coating; IPC-2221B (November 2012), Table 6-1, column A5: external conductors with conformal coating over assembly; IPC-2221B (November 2012), Table 6-1, column A6: external component lead/termination, uncoated, sea level to 3,050 m; IPC-2221B (November 2012), Table 6-1, column A7: external component lead/termination with conformal coating.
Formula
IPC-2221B (2012) Table 6-1 and §6.3, as given by pcbsync, Altium and trafolo (agreeing cell for cell)
| Symbol | Quantity | Your value |
|---|---|---|
| dmin | Minimum conductor spacing (mm) | — |
| V | Applied voltage (DC or peak AC) (V) | 50 V |
| h | Operating altitude (m) | 0 m |
| rcol | The column's per-volt spacing above 500 V (mm/V) | — |
Assumptions
5 items
- 01IPC-2221B Table 6-1 is read as a step: a voltage inside a band (0–15, 16–30, 31–50, 51–100, 101–150, 151–170, 171–250, 251–300 or 301–500 V) takes that band's value, with no interpolation. The voltage is DC or AC peak between the two conductors.
- 02Above 500 V the column's per-volt figure is added to its 500 V value, as section 6.3 directs: 600 V on B1 needs 0.25 + 100 × 0.0025 = 0.50 mm.
- 03The conditions are the table's columns B1, B2, B4, A5, A6 and A7. Above 3,050 m uncoated external conductors (B2) take column B3, and A6 has no value, so no verdict is given; the other columns do not change with altitude, and there is no altitude factor beyond that change of column.
- 04The percentage is the minimum spacing over your spacing, so a spacing below the minimum is above 100 % and fails; the compliant voltage is the highest voltage at which your spacing still meets the column, the top of a band at 500 V and below.
- 05This is clearance through air only: creepage, contamination, transient overvoltage and IEC 60664-1 or IEC 62368-1 safety distances are not covered.
Worked example
120 V mains on a bare outer layer
A 120 V RMS mains trace runs 0.8 mm from its neighbour on the uncoated top layer of a board used at sea level. Its peak, 169.7 V, is entered as 170 V. Does 0.8 mm meet IPC-2221B, and what would?
| Step | Expression | Result |
|---|---|---|
| Peak voltage | 120 × √2 | 169.7 V |
| Minimum spacing, column B2 (external, uncoated, up to 3 050 m) | Table 6-1, B2, 151–170 V | 1.25 mm |
| Percent of the limit: the board fails | 1.25 ÷ 0.8 × 100 | 156.3 % |
| Compliant voltage for 0.8 mm (or space them 1.25 mm apart) | Table 6-1, B2, 101–150 V: 0.6 mm ≤ 0.8 mm | 150 V |
| With a permanent polymer coating, column B4 | Table 6-1, B4, 151–170 V | 400 µm |
| Percent of the limit with the coating: the board passes | 0.4 ÷ 0.8 × 100 | 50.0 % |
How it works
IPC-2221B Table 6-1 specifies minimum conductor spacing (clearance through air) based on applied voltage and the conductor's condition, in seven columns. B1 covers internal conductors embedded in laminate where the solid dielectric provides insulation. B2 covers external uncoated conductors from sea level to 3,050 m, and B3 the same conductors above 3,050 m. B4 covers external conductors with a permanent polymer coating such as solder resist, A5 external conductors with conformal coating over the assembly, and A6 and A7 component leads and terminations, uncoated (sea level to 3,050 m) and conformally coated.
The table gives one value per voltage band (0–15V, 16–30V, 31–50V, 51–100V, 101–150V, 151–170V, 171–250V, 251–300V and 301–500V), and a voltage inside a band takes that band's value: there is no interpolation. Above 500V the column's per-volt figure is added to its 500V value, so 600V on B1 needs 0.25 + 100 × 0.0025 = 0.50 mm. Internal spacing (B1) is much smaller than external (B2) because FR4 laminate has a dielectric strength of ~20 kV/mm versus air at ~3 kV/mm.
Altitude enters through the columns. Above 3,050 m (10,007 ft) reduced atmospheric pressure lowers air breakdown voltage, and uncoated external conductors move from column B2 to column B3, which asks for up to ten times the spacing (at 100V, 1.5 mm instead of 0.6 mm). There is no altitude multiplier. Internal conductors (B1) and coated conductors (B4, A5, A7) are unaffected, and A6 has no value above 3,050 m. This matters for avionics, satellites, and high-altitude equipment. The B1 to A5 values used here are those three secondary sources (pcbsync, Altium, trafolo) give for Table 6-1, which agree cell for cell.
Practical tips
- Always use peak voltage (or DC). For rectified AC, include the ripple peak. For switch-mode converters, include flyback spikes
- Solder mask, a permanent polymer coating (B4), reduces required spacing by ~3× compared to bare copper (B2) from 151V to 500V — always mask high-voltage areas
- Add slots or routed channels between high-voltage conductors to increase creepage path beyond the straight-line clearance
- For safety-critical designs (medical, mains-connected), IEC 60664-1 and IEC 62368-1 have stricter requirements than IPC — check both
- At board edges, the clearance requirement applies to the nearest conductor on an adjacent board in the system enclosure
Common mistakes
- Using RMS voltage instead of peak — IPC-2221B requires peak or DC voltage. 240V RMS = 340V peak, which doubles the required spacing
- Applying B1 (internal) spacing to external conductors — internal spacing relies on solid laminate dielectric; external surfaces need much more clearance
- Forgetting the altitude column for aircraft or satellite electronics — above 3,050 m uncoated external conductors take column B3, which asks for 2.5 times the sea-level spacing at 51–100V and ten times at 251–300V
- Confusing clearance with creepage — clearance is through air; creepage is along a surface. PCB surfaces accumulate contamination that reduces surface breakdown voltage
- Not accounting for transients — lightning surge or ESD events can produce momentary voltages far above nominal. Use the worst-case transient voltage for spacing calculation
Frequently asked questions
5 questions
What spacing do I need for 48V DC?
Per IPC-2221B B2 (external uncoated): 48V lies in the 31–50V band, which needs 0.60 mm. For B1 (internal): 0.10 mm. Add your fabricator's minimum clearance capability (typically 0.1 mm) to ensure manufacturability.
Does solder mask count as coating for B4?
Yes — column B4 covers external conductors with a permanent polymer coating, and IPC-2221 counts solder resist to IPC-SM-840 as one. The key requirement is that the coating is permanent and applied as part of the PCB fabrication process, not post-assembly, and that it covers every conductor except the soldering lands; uncoated lands and leads take column A6. B4 is not for boards that need protection from harsh, humid or contaminated environments, and a conformal coating applied after assembly is column A5. Column B3 is not a coating: it is uncoated external conductors above 3,050 m.
How does altitude affect required spacing?
Above 3,050 m (10,007 ft), uncoated external conductors move from column B2 to column B3: at 100V the spacing goes from 0.6 mm to 1.5 mm, and at 300V from 1.25 mm to 12.5 mm. There is no multiplier, so 6,000 m and 12,000 m need the same B3 value. This does not apply to internal (B1) or coated (B4, A5, A7) conductors, or to sealed/pressurised enclosures.
What about DC vs AC at the same voltage?
The table applies equally to DC and peak AC — breakdown depends on instantaneous voltage, not waveform. For AC, always use peak voltage (RMS × √2). For pulsed DC, use the pulse peak.
Can I reduce spacing with conformal coating?
Above 30 V, yes: conformal coating over the assembly (A5) needs the same spacing as a permanent polymer coating (B4), far less than bare external (B2); at 100 V that is 0.13 mm against 0.6 mm. Below 30 V it does not help: A5 needs 0.13 mm, more than B4's 0.05 mm and B2's 0.10 mm. Either way, conformal coating must be verified to have no voids, pinholes, or holidays over high-voltage gaps.
Shop Components
As an Amazon Associate we earn from qualifying purchases.