Skip to content

868 MHz ISM Band

ISM-BänderLizenzfreiLoRaWAN (EU868) · Sigfox · Z-Wave EU
Frequenzbereich
863–870MHz
SRD Band (CEPT/EU)
Mitte
866,5MHz
Mittelwert der Bandgrenzen
Wellenlänge
346mm
344,6 mm–347,4 mm über das Band
λ/4 im freien Raum
86,5mm
Bei der Mittenfrequenz
Streckendämpfung auf 100 m
71,2dB
Freiraum, bei 866,5 MHz

Wer das Band nutzt

EU/CEPT short-range-device su…EU/CEPT short-range-device sub-bands, 863-870 MHz863-865 MHz · 863–865 MHz · h1.3863-865 MHz865-868 MHz · 865–868 MHz · h1.4865-868 MHz868.0-868.6 MHz · 868–868.6 MHz · h1.5868.6-868.7 MHz · 868.6–868.7 MHz · Alarms (Annex 7 a)868.7-869.2 MHz · 868.7–869.2 MHz · h1.6869.2-869.25 MHz · 869.2–869.25 MHz · Social alarms (Annex 7 b)869.25-869.3 MHz · 869.25–869.3 MHz · Alarms (Annex 7 c)869.3-869.4 MHz · 869.3–869.4 MHz · Alarms (Annex 7 d)869.4-869.65 MHz · 869.4–869.65 MHz · h1.7869.65-869.7 MHz · 869.65–869.7 MHz · Alarms (Annex 7 e)869.7-870 MHz · 869.7–870 MHz · h1.8 / h1.9RFID interrogator channels, 8…RFID interrogator channels, 865-868 MHzRFID 1 · 865.7 MHzRFID 1RFID 2 · 866.3 MHzRFID 2RFID 3 · 866.9 MHzRFID 3RFID 4 · 867.5 MHzRFID 4864866868870
h1.3h1.4h1.5Alarms (Annex 7 a)h1.6Social alarms (Annex 7 b)Alarms (Annex 7 c)Alarms (Annex 7 d)h1.7Alarms (Annex 7 e)h1.8 / h1.9BandgrenzenMHz
EU/CEPT short-range-device sub-bands, 863-870 MHzEuropäische Union · Alle 11 Kanäle

Limits per sub-band are in the limits table above.2,3

KanalMitte (MHz)Grenzen (MHz)TeilbandHinweis
863-865 MHz—863–865h1.325 mW e.r.p., 0.1 % or LBT+AFA
865-868 MHz—865–868h1.425 mW e.r.p., 1 % or LBT+AFA; RFID channels inside
868.0-868.6 MHz—868–868,6h1.525 mW e.r.p., 1 %
868.6-868.7 MHz—868,6–868,7Alarms (Annex 7 a)10 mW e.r.p., 1 %
868.7-869.2 MHz—868,7–869,2h1.625 mW e.r.p., 0.1 %
869.2-869.25 MHz—869,2–869,25Social alarms (Annex 7 b)10 mW e.r.p., 0.1 %
869.25-869.3 MHz—869,25–869,3Alarms (Annex 7 c)10 mW e.r.p., 0.1 %
869.3-869.4 MHz—869,3–869,4Alarms (Annex 7 d)10 mW e.r.p., 1 %
869.4-869.65 MHz—869,4–869,65h1.7500 mW e.r.p., 10 %
869.65-869.7 MHz—869,65–869,7Alarms (Annex 7 e)25 mW e.r.p., 10 %
869.7-870 MHz—869,7–870h1.8 / h1.95 mW e.r.p. with no duty cycle, or 25 mW e.r.p. at 1 %
RFID interrogator channels, 865-868 MHzEuropäische Union · Alle 4 Kanäle

2 W e.r.p., 200 kHz maximum bandwidth each; tags reply at about -20 dBm e.r.p. around these channels.2,3

KanalMitte (MHz)Grenzen (MHz)
RFID 1865,7—
RFID 2866,3—
RFID 3866,9—
RFID 4867,5—

Regulatorische Grenzwerte

Lizenzfrei

Licence-exempt short-range devices under EU Decision 2006/771/EC and CEPT ERC/REC 70-03, with power and duty-cycle (or listen-before-talk) conditions per sub-band.2,3

RegionVorschriftBereich (MHz)GrenzwertHinweise
Europäische Union(EU) 2025/105 Annex band 46a; ERC/REC 70-03 Annex 1 h1.3863–86525 mW ERP0,1 % TastgradSpectrum-access techniques per the harmonised standard (e.g. LBT + AFA), or else the duty-cycle limit.2,3
(EU) 2025/105 Annex band 84863–86825 mW ERP10 % Tastgrad · network access points2,8 % Tastgrad · other devicesWideband data transmission in data networks only; bandwidth > 600 kHz and ≤ 1 MHz.2
(EU) 2025/105 Annex band 47; ERC/REC 70-03 Annex 1 h1.4865–86825 mW ERP1 % TastgradSpectrum-access techniques per the harmonised standard, or else the duty-cycle limit.2,3
(EU) 2025/105 Annex band 47a; ERC/REC 70-03 Annex 11 a865–8682 W ERPRFID interrogators, only in the four 200 kHz channels centred on 865.7, 866.3, 866.9 and 867.5 MHz; CEPT adds ≤ 4 s continuous transmission per channel and ≥ 100 ms between transmissions.2,3
(EU) 2025/105 Annex band 47b; ERC/REC 70-03 Annex 2 c1865,6–867,6500 mW ERP10 % Tastgrad · network access points (CEPT)2,5 % Tastgrad · other devices (CEPT)Only in 865.6-865.8, 866.2-866.4, 866.8-867.0 and 867.4-867.6 MHz, with adaptive power control; CEPT limits these data networks to ≤ 200 kHz bandwidth.2,3
(EU) 2025/105 Annex band 48; ERC/REC 70-03 Annex 1 h1.5868–868,625 mW ERP1 % TastgradSpectrum-access techniques or the duty-cycle limit.2,3
(EU) 2025/105 Annex band 49; ERC/REC 70-03 Annex 7 a868,6–868,710 mW ERP1 % TastgradAlarms only; bandwidth ≤ 25 kHz, or the whole sub-band as one channel.2,3
(EU) 2025/105 Annex band 50; ERC/REC 70-03 Annex 1 h1.6868,7–869,225 mW ERP0,1 % TastgradSpectrum-access techniques or the duty-cycle limit.2,3
(EU) 2025/105 Annex band 51869,2–869,2510 mW ERP0,1 % TastgradSocial alarms only; 25 kHz channel spacing.2
(EU) 2025/105 Annex band 52869,25–869,310 mW ERP0,1 % TastgradAlarms only; bandwidth ≤ 25 kHz.2
(EU) 2025/105 Annex band 53869,3–869,410 mW ERP1 % TastgradAlarms only; bandwidth ≤ 25 kHz.2
(EU) 2025/105 Annex band 54; ERC/REC 70-03 Annex 1 h1.7869,4–869,65500 mW ERP10 % TastgradThe high-power sub-band. Spectrum-access techniques or the duty-cycle limit.2,3
(EU) 2025/105 Annex band 55869,65–869,725 mW ERP10 % TastgradAlarms only; bandwidth ≤ 25 kHz.2
(EU) 2025/105 Annex band 56a; ERC/REC 70-03 Annex 1 h1.8869,7–8705 mW ERPNo duty-cycle limit.2,3
(EU) 2025/105 Annex band 56b; ERC/REC 70-03 Annex 1 h1.9869,7–87025 mW ERP1 % TastgradSpectrum-access techniques or the duty-cycle limit.2,3
CEPTERC/REC 70-03 Annex 1 h1.0 (Empfehlung)863–87025 mW ERP0,1 % TastgradFrequency-hopping SRD, ≤ 100 kHz channels, 47 or more hop channels; the duty cycle applies to the whole transmission. Alarm sub-bands excluded.3

Eine Zusammenfassung, keine Rechtsberatung. Prüfen Sie den aktuellen Vorschriftentext für Ihre Region. Fehlt hier eine Region, wurde sie nicht recherchiert; das heißt nicht, dass es dort keine Vorschrift gibt.

Vorschriftenzitate und Hinweise stehen auf Englisch.

ITU-Zuweisung

Not an ITU ISM band: in Region 1, 862-890 MHz is allocated to the fixed, mobile (except aeronautical) and broadcasting services. 863-870 MHz is a short-range-device band by CEPT recommendation and EU decision.

Bereich (MHz)ITU-RegionFunkdiensteFußnoten
862–890Region 1Fixed, Mobile except aeronautical mobile, Broadcasting5.312B, 5.317A, 5.319, 5.322, 5.3231

Primärdienste in Großbuchstaben, Sekundärdienste in normaler Schrift, wie in der VO Funk.

Quellen

  1. 1Radio Regulations, Edition of 2024, Volume 1: ArticlesITU · Edition of 2024 (incorporates WRC-23; in force 1 January 2025) · Article 5, 862-890 MHz (Region 1); Nos. 5.138 and 5.150 (the ITU ISM list, which does not include 863-870 MHz)Abgerufen am 2026-10-21
  2. 2Commission Implementing Decision (EU) 2025/105 amending Decision 2006/771/EC (harmonised technical conditions for short-range devices)European Commission (Official Journal L, 23.1.2025) · OJ L 2025/105 of 23 January 2025; its Annex replaces the Annex of Decision 2006/771/EC · Annex, Table 2, bands 46a, 47, 47a, 47b, 48-56b, 84Abgerufen am 2026-10-21
  3. 3ERC Recommendation 70-03: Relating to the use of Short Range Devices (SRD)CEPT ECC (ECO Documentation Database) · Edition of June 2026 (latest amended 5 June 2026, WG FM#113) · Annex 1 (h1.0-h1.9), Annex 2 (c1), Annex 7 (a-e), Annex 11 (a, note 1)Abgerufen am 2026-10-21

Ausbreitungseigenschaften

Ausgezeichnete Durchdringung durch Wände und Decken. Typische LoRa-Reichweite: 2–15 km in städtischen Gebieten, bis zu 40 km Sichtverbindung.

Anwendungen

  • LoRaWAN (EU868)
  • Sigfox
  • Z-Wave EU
  • Smart Metering
  • Gebäudeautomation
  • Drahtlose Alarmsysteme