Flyback Converter Calculator

POSThttps://rftools.io/api/py/v1/calculate

Slug flyback-converter. Calculate flyback converter turns ratio, peak primary and secondary currents, and power levels for isolated DC-DC converter design.

Inputs

Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.

Inputs of flyback-converter
NameUnitRangeDefaultDescription
vinnumberV1 … 100048DC input voltage
voutnumberV0.5 … 50012Desired output voltage
ioutnumberA0.01 … 1001Maximum output current
efficiencynumber%10 … 9985Expected converter efficiency (typical: 80-90%)
fswnumberkHz10 … 5000100Switching frequency
dutyCyclenumber%5 … 9040Primary switch duty cycle (typical: 30-50% for flyback)
vinMinnumberV0 … 10000The lowest input the converter must work from; 0 for the nominal. The transformer designed at the nominal runs in continuous conduction below it.
vinMaxnumberV0 … 10000The highest input the converter must work from; 0 for the nominal. It sets the switch's and the rectifier's voltage.
rdsOnnumbermΩ0.1 … 10000050The switch FET's on-resistance at its operating temperature.
tFallnumberns0 … 1000020The switch turns off at the peak current: the switching loss is ½·(V_in + n·V_out)·I_pk·t_f·f_sw. It turns on at zero current at the boundary.
qgnumbernC0 … 1000015The switch's gate charge at the drive voltage: the gate drive takes Q_g·V_g·f_sw.
vGatenumberV1 … 2010Gate Drive Voltage
vDiodenumberV0 … 30.5The output rectifier's forward voltage: it dissipates V_F·I_out.
rPrinumbermΩ0 … 10000050Primary Winding Resistance
rSecnumbermΩ0 … 10000020Secondary Winding Resistance
coreLossnumbermW0 … 1000000100From the core's datasheet at this flux swing and frequency.
leakageInductancenumberμH0 … 1000002.6Primary leakage inductance, measured with the secondary shorted; typically 1 to 3 % of the primary inductance. Its energy goes to the clamp.
clampRationumbernone1.1 … 102The clamp voltage as a multiple of the reflected output voltage; AN-4147 suggests 2 to 2.5. A lower clamp spends more of the magnetizing energy in the clamp, a higher one stresses the switch more.

Outputs

Returned in values, by key. A value that is unbounded or undefined is null.

Outputs of flyback-converter
FieldUnitDescription
turnsRatioheadlinenonePrimary-to-secondary turns ratio
iinAvgAAverage DC input current
ipPeakAPeak current in primary MOSFET switch
isecPeakAPeak current in secondary diode/rectifier
outputPowerWTotal output power: Vout × Iout
primaryInductanceμHMagnetizing inductance at which the primary current ramps from zero to the peak in each on-time (boundary conduction): Vin·D/(fsw·Ipk)
dutyMin%At the maximum input voltage, in discontinuous conduction
dutyMax%At the minimum input voltage, in continuous conduction
ipPeakWorstAThe transformer's saturation current must be at least this
ipPeakWorstVinVInput at the Worst Primary Peak
isecPeakWorstAPeak Secondary Current, Worst Case
isecPeakWorstVinVInput at the Worst Secondary Peak
primaryRmsAAIn the switch and the primary winding
primaryRmsVinVInput at the Worst Primary RMS Current
secondaryRmsAAIn the rectifier and the secondary winding
secondaryRmsVinVInput at the Worst Secondary RMS Current
reflectedVoltageVThe output as the primary sees it while the secondary conducts
clampVoltageVAbove the input rail, where the clamp holds the drain after turn-off
vdsPeakWorstVThe maximum input plus the clamp voltage
vdsPeakVinVInput at the Worst Drain Voltage
vdsRatingVThe rating sold at or above the clamped peak drain voltage
diodeVrWorstVThe output plus the maximum input over the turns ratio, while the switch is on
diodeVrVinVInput at the Worst Reverse Voltage
diodeVrRatingVThe rating sold at or above 1.5 times the worst reverse voltage
lossConductionWSwitch Conduction Loss
lossSwitchingWSwitch Turn-off Loss
lossGateDriveWGate Drive Loss
lossDiodeWRectifier Conduction Loss
lossCopperWWinding Copper Loss
lossCoreWTransformer Core Loss
lossClampWThe leakage energy ½·L_lk·I_pk²·f and the magnetizing energy the clamp takes while the leakage resets
lossTotalWTotal Loss
efficiencyLossModel%At the nominal input and load, from the loss model. The currents are sized with the efficiency input; set it to this value and they follow the loss model