Documentation sections
Inductor Energy & Time Constant Calculator
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug inductor-energy. Calculate energy stored in an inductor, L/R time constant, and current rise time
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| inductancenumber | μH | at least 0.001 | 100 | Inductance |
| currentnumber | A | at least 0 | 1 | Current |
| resistancenumber | Ω | at least 0.001 | 10 | Series resistance (winding + external) |
| targetCurrentnumber | % | 1 … 99 | 63.2 | Target current as % of final value |
| requiredTimenumber | μs | at least 0.001 | 20 | The time the design allows for the current to reach its target (a relay's pull-in, a driver's on-time); the rise time must not exceed it |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| energyheadline | μJ | Stored Energy |
| timeConst | μs | Time Constant |
| riseTime | μs | Rise Time to Target |
| peakVoltage | V | Initial Back-EMF |
| saturationCheck | μH·A | Saturation Check (I × L) |
Calling it
- Calculate: one call, the request and response in full, and its errors.
- Batch: this calculator with others, or a sweep, in one request.