Load Cell Amplifier Gain
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug load-cell-amplifier. Calculate load cell output voltage, required amplifier gain, and mV/V sensitivity for Wheatstone bridge weigh scale and force sensor designs.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| excitationVoltagenumber | V | at least 0.1 | 5 | Excitation Voltage |
| sensitivitynumber | mV/V | at least 0.01 | 2 | From load cell datasheet, typically 1–3 mV/V |
| fullScaleLoadnumber | kg | at least 0.001 | 10 | Full-Scale Load |
| gainnumber | V/V | at least 1 | 500 | Amplifier Gain |
| appliedLoadnumber | kg | at least 0 | 5 | The load on the cell, in the same unit as the full-scale load |
| adcRefnumber | V | 0.1 … 50 | 5 | The ADC full scale. 5 V matches the gain this calculator suggests. |
| adcBitsnumber | bit | 1 … 24 | 12 | ADC resolution in bits |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| fullScaleOutputMv | mV | Full-Scale Output |
| amplifiedOutput | V | Amplified Full-Scale |
| sensitivityPerUnit | mV/kg | Sensitivity |
| requiredGainheadline | V/V | Gain for 5V ADC |
| bridgeOutputMv | mV | The load cell output at the applied load |
| amplifiedVoltage | V | The cell output at the applied load times the gain |
| adcCode | none | The code an ideal ADC reads: floor(V_amp / V_ref × 2^N) |
| resolution | kg/LSB | The load one ADC step spans |
Calling it
- Calculate: one call, the request and response in full, and its errors.
- Batch: this calculator with others, or a sweep, in one request.
- Solve for a target: the value of one input that brings an output to a target.