RF Power Density Calculator
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug power-density. Calculate power density in W/m² from EIRP and distance using S = EIRP/(4πd²). Get electric field E in V/m, magnetic field H in A/m, and check FCC & ICNIRP EMF safety exposure limits instantly.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| eirpnumber | dBm | −30 … 80 | 30 | Equivalent Isotropically Radiated Power (transmitter power + antenna gain) |
| distancenumber | m | at least 0.01 | 10 | Distance from the antenna to observation point (far field assumed) |
| frequencynumber | GHz | at least 0.001 | 2.4 | Sets the exposure limit; the far-field power density itself does not depend on it |
| standardnumber | none | 0 … 1 | 0 | The exposure limits the power density is checked against |
| exposureClassnumber | none | 0 … 1 | 0 | General public (uncontrolled) or occupational (controlled) exposure |
| groundReflectionnumber | none | 0 … 1 | 0 | FCC OET Bulletin 65: a ground reflection adding in phase raises the power density by 1.6² = 2.56 |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| powerDensityheadline | mW/m² | RF power density at given distance: S = EIRP / (4π·d²) |
| efield | V/m | Far-field electric field strength: E = √(S × η₀), η₀ = µ₀·c ≈ 376.73 Ω |
| hfield | mA/m | Far-field magnetic field strength: H = E / η₀ |
| planeWaveImpedance | Ω | Free-space plane-wave impedance η₀ = µ₀·c ≈ 376.73 Ω |
| limitDensity | mW/m² | The power-density limit of the chosen standard and exposure class at the frequency |
| limitPercent | % | The power density as a percentage of the limit; above 100 % does not comply |
| minDistance | m | The distance at which the power density equals the limit; at or beyond it the exposure complies |
| maxEirp | dBm | The EIRP at which the power density at this distance equals the limit; at or below it the exposure complies |