Documentation sections
Thermal Resistance Network Calculator
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug thermal-resistance-network. Calculate junction, case, and heatsink temperatures through a series thermal resistance network (θJC + θCS + θSA) for component thermal management
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| powerDissipationnumber | W | at least 0.001 | 5 | Total power dissipated by the device |
| thetaJCnumber | °C/W | at least 0.01 | 2 | Junction-to-case thermal resistance from device datasheet |
| thetaCSnumber | °C/W | at least 0 | 0.5 | Case-to-heatsink thermal resistance (thermal interface material) |
| thetaSAnumber | °C/W | at least 0.1 | 10 | Heatsink-to-ambient thermal resistance (heatsink specification) |
| ambientTempnumber | °C | −55 … 85 | 25 | Ambient Temperature |
| numLayersnumber | none | 0 … 6 | 0 | Thermal layers in series between the case and the heatsink besides θ_CS, such as an insulating pad, a spreader or a board with thermal vias (0–6) |
| layer1Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 1, in series between the case and the heatsink |
| layer2Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 2, in series between the case and the heatsink |
| layer3Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 3, in series between the case and the heatsink |
| layer4Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 4, in series between the case and the heatsink |
| layer5Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 5, in series between the case and the heatsink |
| layer6Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 6, in series between the case and the heatsink |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| junctionTempheadline | °C | Junction Temperature |
| caseTemp | °C | Case Temperature |
| heatsinkTemp | °C | Heatsink Temperature |
| totalThetaJA | °C/W | Total θJA |
| thermalMargin | °C | Thermal Margin (to 150°C) |
Calling it
- Calculate: one call, the request and response in full, and its errors.
- Batch: this calculator with others, or a sweep, in one request.
- Solve for a target: the value of one input that brings an output to a target.