Documentation sections
Heatsink Calculator
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug heatsink-calculator. Calculate required heatsink thermal resistance (θ_SA) and junction temperature for MOSFETs, IGBTs, and power ICs. Verify thermal design feasibility. Free results.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| powerDissipationnumber | W | at least 0 | 5 | Power Dissipation |
| maxJunctionTempnumber | °C | 25 … 200 | 125 | Max Junction Temperature |
| ambientTempnumber | °C | −40 … 85 | 25 | Ambient Temperature |
| thetaJCnumber | °C/W | at least 0.1 | 2 | Junction-to-case thermal resistance from datasheet |
| thetaCSnumber | °C/W | at least 0 | 0.5 | Case-to-heatsink thermal resistance (thermal pad/grease) |
| numLayersnumber | none | 0 … 6 | 0 | Thermal layers in series between the case and the heatsink besides θ_CS, such as an insulating pad, a spreader or a board with thermal vias (0–6) |
| layer1Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 1, in series between the case and the heatsink |
| layer2Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 2, in series between the case and the heatsink |
| layer3Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 3, in series between the case and the heatsink |
| layer4Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 4, in series between the case and the heatsink |
| layer5Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 5, in series between the case and the heatsink |
| layer6Thetanumber | °C/W | 0 … 100 | 1 | Thermal resistance of extra layer 6, in series between the case and the heatsink |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| thetaSA_requiredheadline | °C/W | Required heatsink-to-ambient thermal resistance — lower is better |
| junctionTemp | °C | Junction Temperature |
| thetaJA_total | °C/W | Total θ_JA |
| tempRise | °C | Temperature Rise |
| thetaJS | °C/W | The stack between the junction and the heatsink: θ_JC + θ_CS + the extra layers |
| heatsinkTemp | °C | Temperature of the heatsink where the device mounts: T_J − P_D·θ_JS |
Calling it
- Calculate: one call, the request and response in full, and its errors.
- Batch: this calculator with others, or a sweep, in one request.
- Solve for a target: the value of one input that brings an output to a target.