Rotary Phase Converter Calculator — Idler and Balancing Capacitors
Slug rotary-phase-converter. Size the balancing capacitors of a rotary phase converter: the idler motor generates the third leg from a single-phase supply, and capacitors from that leg to each supply line even out the three voltages. See the set that balances the idler alone, the set for the load motor at full load, the capacitance to switch in between them, and what each set does at the other load, with the idler's winding current and its start capacitor.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| supplyVoltagenumber | V | at least 1 | 230 | The single-phase supply, equal to both motors' rated line voltage in the connection used. |
| frequencynumber | Hz | at least 1 | 50 | Supply Frequency |
| idlerCurrentnumber | A | at least 0.001 | 13.5 | The idler's nameplate current at the supply voltage; the idler is a three-phase motor running unloaded. |
| idlerNoLoadCurrentnumber | % | 1 … 99 | 35 | The idler's current running unloaded on a balanced supply, as a percentage of its rated current. |
| idlerNoLoadPFnumber | none | 0.01 … 1 | 0.1 | The idler's power factor running unloaded; 0.05 to 0.2 is typical. |
| loadCurrentnumber | A | at least 0.001 | 8.3 | The nameplate current of the machine the converter runs, at the supply voltage. |
| loadPowerFactornumber | none | 0.01 … 1 | 0.81 | The load motor's nameplate cos φ at rated load. |
| lockedRotorRationumber | × | at least 1.01 | 6 | Starting current as a multiple of rated, taken the same for both motors; 5 to 7 is typical. |
| lockedRotorPFnumber | none | 0.01 … 1 | 0.4 | Power factor at standstill, taken the same for both motors; 0.3 to 0.5 is typical of small cage motors. |
| startTorqueTargetnumber | % | at least 1 | 25 | Starting torque wanted from the idler, as a percentage of its three-phase locked-rotor torque; an unloaded idler needs little. |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| idleCapacitor31headline | µF | Idle Set: Capacitor L3–L1 |
| fullCapacitor31 | µF | Full-Load Set: Capacitor L3–L1 |
| switchedCapacitor31 | µF | Capacitance to Switch In (L3–L1) |
| idleSetFullUnbalance | % | Idle Set Under Full Load: Unbalance |
| idleSetFullLoadCurrent | % | Idle Set Under Full Load: Load-Motor Winding, % of Rated |
| idleCapacitor32 | µF | Capacitor L3–L2 |
| idleInductor32 | mH | Inductor L3–L2 |
| fullCapacitor32 | µF | Capacitor L3–L2 |
| fullInductor32 | mH | Inductor L3–L2 |
| fullCapsFullUnbalance | % | Unbalance at Full Load, Capacitors Only |
| fullCapsFullLoadCurrent | % | Load-Motor Winding at Full Load, Capacitors Only, % of Rated |
| noPartsVoltage23 | V | Voltage L2–L3 |
| noPartsVoltage31 | V | Voltage L3–L1 |
| noPartsUnbalance | % | Voltage Unbalance (V₂/V₁) |
| idleSetFullVoltage23 | V | Voltage L2–L3 |
| idleSetFullVoltage31 | V | Voltage L3–L1 |
| idleSetFullIdlerCurrent | % | Idler Winding, % of Rated |
| fullCapsIdleVoltage23 | V | Voltage L2–L3 |
| fullCapsIdleVoltage31 | V | Voltage L3–L1 |
| fullCapsIdleUnbalance | % | Voltage Unbalance |
| fullCapsIdleIdlerCurrent | % | Idler Winding, % of Rated |
| idlerStartCapacitor | µF | Start Capacitor to Add (L3–L1) |
| idlerStartVoltage | V | Capacitor Voltage at Standstill |
| idlerMaxStartTorque | % | Highest Starting Torque Without Over-Voltage |