Documentation sections
EMI Margin Budget
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug emi-margin-budget. Calculate EMI compliance margin with measurement uncertainty and safety margin. Predict CISPR/FCC pre-compliance test pass or fail instantly.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| measuredLevelnumber | dBμV/m | at least −100 | 30 | Measured Emission Level |
| limitLevelnumber | dBμV/m | at least −100 | 40 | CISPR 22 Class B radiated: 40 dBμV/m (30–230 MHz) at 3m |
| measurementUncertaintynumber | dB | at least 0 | 6 | Typically 6 dB for pre-compliance setups |
| safetyMarginnumber | dB | at least 0 | 6 | Design Safety Margin |
| marginTermsnumber | none | 0 … 6 | 0 | How many further allowances the budget holds back (0–6) |
| term1Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
| term2Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
| term3Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
| term4Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
| term5Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
| term6Allowancenumber | dB | 0 … 40 | 0 | A further allowance held back from the margin, such as unit-to-unit spread, cable layout or the correlation between a pre-compliance set-up and the accredited site |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| rawMargin | dB | Raw Margin |
| adjustedMarginheadline | dB | Adjusted Margin |
| requiredReduction | dB | Reduction Required |
| totalAllowance | dB | Measurement uncertainty, safety margin and every further allowance, added |
Calling it
- Calculate: one call, the request and response in full, and its errors.
- Batch: this calculator with others, or a sweep, in one request.
- Solve for a target: the value of one input that brings an output to a target.