ESD Clamp Diode Selection
POSThttps://rftools.io/ api/ py/ v1/ calculate
Slug esd-clamp-selection. Calculate ESD clamp diode peak current, power dissipation, and clamping ratio. Verify TVS protection for IEC 61000-4-2 compliance.
Inputs
Send every one of these in inputs, in the units shown. Most are required: a call without one is refused (400) and costs nothing; one the calculator can do without takes the default shown. An input outside its range is still computed and flagged in the provenance.
| Name | Unit | Range | Default | Description |
|---|---|---|---|---|
| esdVoltagenumber | V | at least 100 | 4000 | IEC 61000-4-2 Level 4: ±8 kV contact |
| clampVoltagenumber | V | at least 1 | 15 | TVS clamping voltage at peak current from datasheet |
| lineImpedancenumber | Ω | at least 0.1 | 330 | Series resistance in ESD discharge path |
| standardnumber | none | 0 … 1 | 0 | IEC 61000-4-2 contact discharge (preferred) or air discharge (where contact is not possible) |
| testLevelnumber | none | 1 … 4 | 4 | The IEC 61000-4-2 test level the product must pass; the product standard sets it |
Outputs
Returned in values, by key. A value that is unbounded or undefined is null.
| Field | Unit | Description |
|---|---|---|
| peakCurrentheadline | A | Peak Clamp Current |
| clampPower | W | Peak Power Dissipation |
| voltageMargin | V | Voltage Margin |
| clampingRatio | none | Clamping Ratio |
| testVoltage | V | The IEC 61000-4-2 test voltage of the chosen discharge method and level: the least strike voltage the clamp must be checked at |
| limitPercent | % | The test voltage as a percentage of the strike voltage checked; above 100 % the check is below the test level |