Skip to content

NTC Thermistor Temperature Calculator

Calculate temperature from NTC thermistor resistance using the Steinhart-Hart beta equation. Get Kelvin and Celsius outputs for sensor circuit design.

β-parameter equation · 1/T = 1/T₀ + ln(R/R₀)/βAPI slug ntc-thermistor

Sign in to saveSave

Sensor and circuit

Example
Sensor
Thermistor resistance at reference temperature T0 (e.g. 10kΩ at 25°C)

100 mΩ or more

Beta (B) coefficient of the thermistor, from datasheet. Typically 3000–4500 K.

100 to 10 000 K

Reference temperature at which R0 is specified (usually 25°C)

−55 to +200°C

Circuit
The divider's fixed resistor: from the reference to the ADC node when the NTC is on the low side, from the ADC node to ground when it is on the high side

1 Ω or more

The voltage across the divider, which is also the ADC full scale (ratiometric)

100 mV to 50 V

ADC resolution in bits
bit

1 to 24 bit

3.3 V10 kΩADCNTC

Convert

kΩ

1 Ω to 100 MΩ

Temperature
25°C
Divider Output
1.65V
ADC Code
2 048
0x800
Temperature (Kelvin)
298.1K
Resolution
0.02198°C/LSB

Transfer curves

Finest resolution 0.0215 °C/LSB at 19.1 °C
1 kΩ10 kΩ100 kΩ050100 °CMeasured Resistance
5001 0001 5002 0002 5003 0003 500050100 °CADC Code

Lookup table

Every 5 °C from −40 °C to 125 °C
CSV (sign in)
TemperatureMeasured ResistanceDivider OutputADC Code
−40°C401.9kΩ3.22V3 996
−35°C281.6kΩ3.187V3 955
−30°C200.2kΩ3.143V3 901
−25°C144.3kΩ3.086V3 830
−20°C105.4kΩ3.014V3 741
−15°C77.9kΩ2.925V3 630
−10°C58.25kΩ2.816V3 495
−5°C44.03kΩ2.689V3 337
0°C33.62kΩ2.543V3 156
5°C25.92kΩ2.381V2 955
10°C20.17kΩ2.206V2 738
15°C15.84kΩ2.023V2 510
20°C12.54kΩ1.836V2 278
25°C10kΩ1.65V2 048
30°C8.037kΩ1.47V1 825
35°C6.506kΩ1.301V1 614
40°C5.301kΩ1.143V1 419
45°C4.348kΩ1V1 241
50°C3.588kΩ871.4mV1 081
55°C2.978kΩ757.3mV939
60°C2.486kΩ657.1mV815
65°C2.086kΩ569.7mV707
70°C1.76kΩ493.8mV612
75°C1.492kΩ428.4mV531
80°C1.27kΩ372mV461
85°C1.087kΩ323.5mV401
90°C933.6Ω281.8mV349
95°C805.4Ω246mV305
100°C697.5Ω215.2mV267
105°C606.4Ω188.7mV234
110°C529.1Ω165.8mV205
115°C463.3Ω146.1mV181
120°C407.1Ω129.1mV160
125°C358.8Ω114.3mV141

Formula

1T=1T0+1βln⁡(RR0)\frac{1}{T} = \frac{1}{T_0} + \frac{1}{\beta} \ln\left(\frac{R}{R_0}\right)
SymbolQuantityYour value
TTemperature (K)25 °C
T₀Reference temperature (K)25 °C
βBeta coefficient (K)3 950 K
RMeasured resistance (Ω)10 kΩ
R₀Reference resistance at T₀ (Ω)10 kΩ

Assumptions

6 items
  1. 01The thermistor follows the β equation, 1/T = 1/T₀ + ln(R/R₀)/β, with one β over the whole range and 273.15 between kelvin and °C; the Steinhart–Hart third-order term is not used, so far from T₀ the result is only as good as one β fits the part.
  2. 02The NTC and the fixed resistor divide the ADC reference, which is also the ADC full scale, so the reading is ratiometric: V_out = V_ref × R/(R + R_fixed) with the NTC on the low side, V_ref × R_fixed/(R + R_fixed) on the high side.
  3. 03The ADC is an ideal unipolar N-bit converter with no offset, gain error, INL, DNL or noise, and its input draws no current from the divider: code = floor(V_out/V_ref × 2^N), held between 0 and 2^N − 1.
  4. 04A code typed in is read at the middle of its step, (code + 0.5)/2^N × V_ref, and turned back into resistance and temperature through the same divider and β equation.
  5. 05Resolution is the local slope T²(R + R_fixed)²/(β × R × R_fixed × 2^N), in kelvin (the same as °C) per step, and is the same with the NTC on either side.
  6. 06Self-heating from the divider current and the resistance of the leads are not modelled.

Worked example

Code 1 000 from a 10 kΩ NTC

Firmware on a 3.3 V, 12-bit MCU reads code 1 000 from a 10 kΩ, β 3 950 NTC on the low side of a divider, with a 10 kΩ resistor up to the 3.3 V reference. Read at the middle of that step, what temperature is it?

StepExpressionResult
Voltage at the middle of code 1 000(1 000 + ½) / 2^12 × 3.3 V806.1 mV
Thermistor resistance10 kΩ × 0.8061 / (3.3 − 0.8061)3.232 kΩ
Temperature from the β equation1 / (1/(25 + 273.15) + ln(3 232 / 10 000) / 3 950) − 273.1552.79 °C
Code the ADC reads therefloor(0.8061 / 3.3 × 2^12)1 000
Resolution at this point325.9² × (3 232 + 10 000)² / (3 950 × 3 232 × 10 000 × 2^12)0.03557 °C/LSB

How it works

This calculator converts NTC thermistor resistance to temperature using the Steinhart-Hart equation, essential for embedded systems engineers, IoT developers, and industrial control designers who need accurate temperature sensing from -40 to +125 C. NTC (Negative Temperature Coefficient) thermistors decrease resistance as temperature rises, following R(T) = R25 * exp(B * (1/T - 1/298.15)), where B is the material constant (typically 3000-5000 K per manufacturer datasheets). According to IEC 60539-1, standard NTC thermistors achieve +/-1% resistance tolerance at 25 C, translating to +/-0.2 C accuracy. The Steinhart-Hart three-coefficient model (a + b*ln(R) + c*ln(R)^3 = 1/T) provides +/-0.02 C accuracy across the full range per NIST calibration guidelines. Industrial-grade NTCs from Vishay, Murata, and TDK specify B-values with +/-1% tolerance, yielding +/-0.5 C measurement uncertainty over -40 to +85 C operating range. Response time (tau63) ranges from 0.5 s for bare-chip sensors to 15 s for encapsulated probes in still air per IEC 60539-2 test methods.

Practical tips

  • Use manufacturer lookup tables or Steinhart-Hart coefficients from the datasheet for +/-0.1 C accuracy; the simplified B-equation is only +/-1 C accurate per NIST Technical Note 1297
  • Limit excitation current to 100 uA for precision measurement to keep self-heating below 0.01 C per IEC 60539-2 recommendations
  • For linearization, add a parallel resistor equal to R25 to achieve +/-3% linearity over +/-25 C span around the center point per Vishay application note AN-NTCS-1

Common mistakes

  • Using a generic B-value (3950 K) instead of the datasheet-specific value causes +/-2-5 C errors at temperature extremes; Murata NCP series specifies B25/50 vs B25/85 separately with up to 3% difference
  • Forgetting Kelvin conversion: using 25 instead of 298.15 K in the equation produces nonsensical negative temperatures or overestimates by 10-20 C
  • Ignoring self-heating: 1 mA through a 10 kOhm NTC at 25 C dissipates 10 mW, raising sensor temperature by 0.1-1.0 C depending on thermal coupling per IEC 60539-1 dissipation constant specification

Frequently asked questions

2 questions
What does NTC mean and how does it differ from PTC?

NTC (Negative Temperature Coefficient) resistance decreases 3-5%/C as temperature rises, following an exponential curve. PTC (Positive Temperature Coefficient) resistance increases with temperature. NTCs are preferred for temperature measurement due to their 10x higher sensitivity (typically -4%/C vs +0.4%/C for platinum RTDs per IEC 60751), while PTCs are used for overcurrent protection where resistance sharply increases above a threshold.

How accurate are NTC thermistors compared to RTDs?

NTCs achieve +/-0.1 to +/-1 C accuracy depending on calibration, comparable to Class B RTDs (+/-0.3 C at 0 C per IEC 60751). Key differences: NTCs have 10x higher sensitivity (better resolution), lower cost (USD 0.10-2 vs USD 5-50 for RTDs), but narrower range (-40 to +125 C vs -200 to +850 C for platinum RTDs). For industrial temperature measurement from -40 to +150 C, interchangeable NTCs meeting IEC 60539-1 provide +/-0.2 C accuracy at a fraction of RTD cost.