Skin Depth Calculator
Calculate skin depth and surface resistance for copper, aluminum, and other conductors at any frequency. Essential for RF shielding and PCB design. Free, instant results.
Good-conductor skin depth δ = 1/√(πfµσ) · Rs = 1/(σδ)API slug skin-depth
Results
LiveSkin Depth 2.09 µm
- Skin Depthδ
- 2 090nm
- Surface ResistanceRₛ
- 8.25mΩ/□
Skin Depth against Frequency
Drag the operating point or type a value.
Formula
Griffiths, "Introduction to Electrodynamics" 4th ed., Chapter 9
| Symbol | Quantity | Your value |
|---|---|---|
| δ | Skin depth (m) | 2.09 µm |
| ω | Angular frequency (2πf) (rad/s) | — |
| μ | Magnetic permeability (μ₀·μᵣ) (H/m) | — |
| σ | Electrical conductivity (S/m) | 58 000 000 S/m |
Assumptions
5 items
- 01Good conductor: δ = 1/√(π·f·µ₀·µr·σ), valid while conduction current dominates displacement current (σ ≫ ωε).
- 02µ₀ = 4π×10⁻⁷ H/m and µr is a constant, so magnetic saturation and frequency-dependent permeability are not modelled.
- 03A flat, smooth, homogeneous conductor much thicker than δ; surface roughness, plating layers and curvature are not modelled.
- 04Surface resistance is R_s = 1/(σ·δ), the resistance of one square of conductor much thicker than δ.
- 05Conductivity is taken as entered, at one temperature; the default 5.8×10⁷ S/m is annealed copper at 20 °C.
Worked example
Copper trace at 5.8 GHz Wi-Fi
A 5.8 GHz Wi-Fi trace in 1 oz (35 µm) copper, taken as annealed copper with σ = 58 MS/m and µr = 1.
| Step | Expression | Result |
|---|---|---|
| Skin depth | 1 / √(π × 5.8 GHz × 4π×10⁻⁷ × 1 × 58 MS/m) | 0.8677 µm |
| Surface resistance | 1 / (58 MS/m × 0.8677 µm) | 19.87 mΩ/□ |
| Foil thickness in skin depths | 35 µm / 0.8677 µm | 40.3 |
| Depth carrying most current | 3 × 0.8677 µm | 2.60 µm |
How it works
Skin depth calculator computes AC current penetration depth for any conductor material and frequency — RF circuit designers, EMC engineers, and PCB layout specialists use this to optimize trace thickness, shielding effectiveness, and high-frequency conductor performance. The skin depth delta = sqrt(2*rho/(omega*mu)) = sqrt(rho/(pi*f*mu)) represents the depth at which current density falls to 1/e (37%) of its surface value, per Jackson's 'Classical Electrodynamics' (3rd ed.) and IEEE Standard 1597.1.
For copper at room temperature (rho = 1.68e-8 ohm-m), skin depth follows delta_Cu = 66/sqrt(f_MHz) micrometers. At 1 MHz, delta = 66 um; at 100 MHz, delta = 6.6 um; at 1 GHz, delta = 2.1 um; at 10 GHz, delta = 0.66 um. This explains why PCB traces behave differently at RF: a 35 um (1 oz) copper trace carries current through its full thickness at 1 MHz but only the outer 2 um at 1 GHz — effectively reducing conductor cross-section by 15x.
Surface roughness becomes critical when comparable to skin depth: Ra = 1 um roughness causes 10-15% resistance increase at 1 GHz (delta = 2.1 um) per Hammerstad's model. Premium RF laminates specify Ra < 0.5 um (rolled annealed copper) versus standard ED copper at Ra = 2-3 um. Silver plating (rho = 1.59e-8) provides 3% improvement; gold plating (rho = 2.44e-8) is 20% worse than copper but prevents oxidation critical for connector contacts.
Practical tips
- For RF PCBs above 1 GHz, specify rolled annealed (RA) copper with Ra < 1 um surface roughness — standard electrodeposited (ED) copper roughness dominates loss above 3 GHz
- Conductor thickness beyond 3 skin depths provides negligible improvement — 35 um copper is adequate at 1 GHz (delta = 2.1 um), but 70 um (2 oz) may be needed at 100 MHz (delta = 6.6 um) for low loss
- For magnetic shielding, skin depth in steel or mu-metal is much smaller due to high permeability — at 60 Hz, delta_steel approximately equals 0.5 mm versus 8.5 mm for copper; thin steel provides effective low-frequency shielding
Common mistakes
- Ignoring skin effect in high-frequency power calculations — DC resistance is meaningless above 1 MHz; a 10 AWG wire with 3.3 mohm/m DC resistance shows 33 mohm/m at 100 MHz due to skin effect
- Assuming linear current distribution instead of exponential decay — current density at depth d is J(d) = J_surface * exp(-d/delta); 63% of current flows in the first skin depth, 86% in two skin depths, 95% in three
- Overlooking surface roughness at microwave frequencies — standard PCB copper (Ra = 2 um) causes 50-100% resistance increase above 5 GHz; specify low-profile copper (Ra < 0.5 um) for RF traces
- Using gold plating on RF conductors — gold's higher resistivity (1.45x copper) increases loss; gold is for corrosion protection on contacts, not for RF current conduction
Frequently asked questions
5 questions
How does skin depth change with frequency?
Skin depth is inversely proportional to sqrt(frequency): delta = sqrt(rho/(pi*f*mu)). Doubling frequency reduces skin depth by factor of sqrt(2) = 1.41. For copper: 1 MHz = 66 um, 10 MHz = 21 um, 100 MHz = 6.6 um, 1 GHz = 2.1 um, 10 GHz = 0.66 um. This sqrt(f) dependence means skin effect transitions gradually — there's no sharp cutoff where it 'turns on'. Skin effect becomes significant when delta approaches conductor thickness: for 35 um PCB copper, this occurs around 4 MHz.
Does skin depth affect all metals equally?
No — skin depth depends on both resistivity and magnetic permeability: delta = sqrt(rho/(pi*f*mu)). Non-magnetic conductors (copper, aluminum, silver, gold) have mu = mu_0 and differ only by resistivity: delta_Ag/delta_Cu = sqrt(1.59/1.68) = 0.97 (silver 3% better). Magnetic conductors (iron, nickel, steel) have mu >> mu_0, dramatically reducing skin depth: at 1 MHz, delta_Cu = 66 um but delta_steel approximately 0.5 um for mu_r = 100. This makes steel effective for magnetic shielding but poor for RF conductors.
What practical implications does skin depth have?
Key applications: (1) PCB loss: trace resistance at RF is t/(2*delta) times DC resistance; dominates insertion loss above 1 GHz. (2) Shielding: enclosure skin depth determines SE at low frequencies; 1 mm copper provides 30 dB at 100 Hz but only where skin depth (660 um) fits twice. (3) Cable design: Litz wire (many thin insulated strands) reduces skin effect below 500 kHz. (4) Connector plating: thin silver/gold over copper provides corrosion protection without excessive loss since RF current stays in outer 3*delta. (5) Waveguide: interior surface plating (50 um silver) captures essentially all current at microwave frequencies.
Can skin depth be mitigated?
Partially: (1) Litz wire uses many thin strands (each < 2*delta at operating frequency) individually insulated, then twisted — reduces AC/DC resistance ratio from 10x to < 2x at 100 kHz-1 MHz; ineffective above 2 MHz. (2) Higher-conductivity plating: silver provides 3% improvement over copper. (3) Surface smoothing: reducing Ra roughness from 2 um to 0.3 um saves 50% resistance at 10 GHz. (4) Wider conductors: doubling width halves resistance without fighting skin effect. (5) Hollow conductors: tube with wall thickness 3-5*delta has same RF resistance as solid conductor with far less weight — used in high-power antenna elements.
Is skin depth important in low-frequency applications?
Skin effect becomes significant when skin depth is comparable to conductor dimension. For 10 AWG wire (2.6 mm diameter): at 60 Hz, delta_Cu = 8.5 mm >> 2.6 mm — negligible skin effect. At 10 kHz, delta = 0.66 mm — moderate effect, R_AC/R_DC approximately 1.5. At 100 kHz, delta = 0.21 mm — substantial effect, R_AC/R_DC approximately 5. Power transformers (50-60 Hz) use solid conductors; switching power supplies (100 kHz+) require Litz wire or foil conductors. Audio frequencies (20 Hz-20 kHz) have negligible skin effect in typical wire gauges but measurable effect in large power cables.
References
Microwave Engineering, 4th ed. · Classical Electrodynamics, 3rd ed.
- Microwave Engineering, 4th ed. — David M. Pozar (2011), Chapter 1.6 — Skin depth and surface resistance
- Classical Electrodynamics, 3rd ed. — John D. Jackson (1999), Chapter 5 — Skin effect in conductors
Shop Components