Skip to content

Skin Depth Calculator

Calculate skin depth and surface resistance for copper, aluminum, and other conductors at any frequency. Essential for RF shielding and PCB design. Free, instant results.

Good-conductor skin depth δ = 1/√(πfµσ) · Rs = 1/(σδ)API slug skin-depth

Sign in to saveSave

Inputs

Example
Operating frequency

1 kHz to 1 THz

Electrical conductivity of the conductor material

1 000 to 100 000 000 S/m

Relative magnetic permeability of the conductor (1 for non-magnetic materials)

1 to 100 000

Results

Live

Skin Depth 2.09 µm

Skin Depthδ
2.09µm
Skin Depthδ
2 090nm
Surface ResistanceRₛ
8.25mΩ/□

Skin Depth against Frequency

0.11101001 00010 kHz1 MHz100 MHz10 GHzµm

Drag the operating point or type a value.

Formula

Griffiths, "Introduction to Electrodynamics" 4th ed., Chapter 9
δ=2ωμσ=1πfμ0μrσ\delta = \sqrt{\frac{2}{\omega \mu \sigma}} = \sqrt{\frac{1}{\pi f \mu_0 \mu_r \sigma}}
SymbolQuantityYour value
δSkin depth (m)2.09 µm
ωAngular frequency (2πf) (rad/s)—
μMagnetic permeability (μ₀·μᵣ) (H/m)—
σElectrical conductivity (S/m)58 000 000 S/m
With your inputs
δ = 1 / √(π × 1 GHz × μ₀ × 1 × 58 000 000 S/m)2.09 µm
R_s = 1 / (58 000 000 S/m × δ)8.25 mΩ/□

Assumptions

5 items
  1. 01Good conductor: δ = 1/√(π·f·µ₀·µr·σ), valid while conduction current dominates displacement current (σ ≫ ωε).
  2. 02µ₀ = 4π×10⁻⁷ H/m and µr is a constant, so magnetic saturation and frequency-dependent permeability are not modelled.
  3. 03A flat, smooth, homogeneous conductor much thicker than δ; surface roughness, plating layers and curvature are not modelled.
  4. 04Surface resistance is R_s = 1/(σ·δ), the resistance of one square of conductor much thicker than δ.
  5. 05Conductivity is taken as entered, at one temperature; the default 5.8×10⁷ S/m is annealed copper at 20 °C.

Worked example

Copper trace at 5.8 GHz Wi-Fi

A 5.8 GHz Wi-Fi trace in 1 oz (35 µm) copper, taken as annealed copper with σ = 58 MS/m and µr = 1.

StepExpressionResult
Skin depth1 / √(π × 5.8 GHz × 4π×10⁻⁷ × 1 × 58 MS/m)0.8677 µm
Surface resistance1 / (58 MS/m × 0.8677 µm)19.87 mΩ/□
Foil thickness in skin depths35 µm / 0.8677 µm40.3
Depth carrying most current3 × 0.8677 µm2.60 µm

How it works

Skin depth calculator computes AC current penetration depth for any conductor material and frequency — RF circuit designers, EMC engineers, and PCB layout specialists use this to optimize trace thickness, shielding effectiveness, and high-frequency conductor performance. The skin depth delta = sqrt(2*rho/(omega*mu)) = sqrt(rho/(pi*f*mu)) represents the depth at which current density falls to 1/e (37%) of its surface value, per Jackson's 'Classical Electrodynamics' (3rd ed.) and IEEE Standard 1597.1.

For copper at room temperature (rho = 1.68e-8 ohm-m), skin depth follows delta_Cu = 66/sqrt(f_MHz) micrometers. At 1 MHz, delta = 66 um; at 100 MHz, delta = 6.6 um; at 1 GHz, delta = 2.1 um; at 10 GHz, delta = 0.66 um. This explains why PCB traces behave differently at RF: a 35 um (1 oz) copper trace carries current through its full thickness at 1 MHz but only the outer 2 um at 1 GHz — effectively reducing conductor cross-section by 15x.

Surface roughness becomes critical when comparable to skin depth: Ra = 1 um roughness causes 10-15% resistance increase at 1 GHz (delta = 2.1 um) per Hammerstad's model. Premium RF laminates specify Ra < 0.5 um (rolled annealed copper) versus standard ED copper at Ra = 2-3 um. Silver plating (rho = 1.59e-8) provides 3% improvement; gold plating (rho = 2.44e-8) is 20% worse than copper but prevents oxidation critical for connector contacts.

Practical tips

  • For RF PCBs above 1 GHz, specify rolled annealed (RA) copper with Ra < 1 um surface roughness — standard electrodeposited (ED) copper roughness dominates loss above 3 GHz
  • Conductor thickness beyond 3 skin depths provides negligible improvement — 35 um copper is adequate at 1 GHz (delta = 2.1 um), but 70 um (2 oz) may be needed at 100 MHz (delta = 6.6 um) for low loss
  • For magnetic shielding, skin depth in steel or mu-metal is much smaller due to high permeability — at 60 Hz, delta_steel approximately equals 0.5 mm versus 8.5 mm for copper; thin steel provides effective low-frequency shielding

Common mistakes

  • Ignoring skin effect in high-frequency power calculations — DC resistance is meaningless above 1 MHz; a 10 AWG wire with 3.3 mohm/m DC resistance shows 33 mohm/m at 100 MHz due to skin effect
  • Assuming linear current distribution instead of exponential decay — current density at depth d is J(d) = J_surface * exp(-d/delta); 63% of current flows in the first skin depth, 86% in two skin depths, 95% in three
  • Overlooking surface roughness at microwave frequencies — standard PCB copper (Ra = 2 um) causes 50-100% resistance increase above 5 GHz; specify low-profile copper (Ra < 0.5 um) for RF traces
  • Using gold plating on RF conductors — gold's higher resistivity (1.45x copper) increases loss; gold is for corrosion protection on contacts, not for RF current conduction

Frequently asked questions

5 questions
How does skin depth change with frequency?

Skin depth is inversely proportional to sqrt(frequency): delta = sqrt(rho/(pi*f*mu)). Doubling frequency reduces skin depth by factor of sqrt(2) = 1.41. For copper: 1 MHz = 66 um, 10 MHz = 21 um, 100 MHz = 6.6 um, 1 GHz = 2.1 um, 10 GHz = 0.66 um. This sqrt(f) dependence means skin effect transitions gradually — there's no sharp cutoff where it 'turns on'. Skin effect becomes significant when delta approaches conductor thickness: for 35 um PCB copper, this occurs around 4 MHz.

Does skin depth affect all metals equally?

No — skin depth depends on both resistivity and magnetic permeability: delta = sqrt(rho/(pi*f*mu)). Non-magnetic conductors (copper, aluminum, silver, gold) have mu = mu_0 and differ only by resistivity: delta_Ag/delta_Cu = sqrt(1.59/1.68) = 0.97 (silver 3% better). Magnetic conductors (iron, nickel, steel) have mu >> mu_0, dramatically reducing skin depth: at 1 MHz, delta_Cu = 66 um but delta_steel approximately 0.5 um for mu_r = 100. This makes steel effective for magnetic shielding but poor for RF conductors.

What practical implications does skin depth have?

Key applications: (1) PCB loss: trace resistance at RF is t/(2*delta) times DC resistance; dominates insertion loss above 1 GHz. (2) Shielding: enclosure skin depth determines SE at low frequencies; 1 mm copper provides 30 dB at 100 Hz but only where skin depth (660 um) fits twice. (3) Cable design: Litz wire (many thin insulated strands) reduces skin effect below 500 kHz. (4) Connector plating: thin silver/gold over copper provides corrosion protection without excessive loss since RF current stays in outer 3*delta. (5) Waveguide: interior surface plating (50 um silver) captures essentially all current at microwave frequencies.

Can skin depth be mitigated?

Partially: (1) Litz wire uses many thin strands (each < 2*delta at operating frequency) individually insulated, then twisted — reduces AC/DC resistance ratio from 10x to < 2x at 100 kHz-1 MHz; ineffective above 2 MHz. (2) Higher-conductivity plating: silver provides 3% improvement over copper. (3) Surface smoothing: reducing Ra roughness from 2 um to 0.3 um saves 50% resistance at 10 GHz. (4) Wider conductors: doubling width halves resistance without fighting skin effect. (5) Hollow conductors: tube with wall thickness 3-5*delta has same RF resistance as solid conductor with far less weight — used in high-power antenna elements.

Is skin depth important in low-frequency applications?

Skin effect becomes significant when skin depth is comparable to conductor dimension. For 10 AWG wire (2.6 mm diameter): at 60 Hz, delta_Cu = 8.5 mm >> 2.6 mm — negligible skin effect. At 10 kHz, delta = 0.66 mm — moderate effect, R_AC/R_DC approximately 1.5. At 100 kHz, delta = 0.21 mm — substantial effect, R_AC/R_DC approximately 5. Power transformers (50-60 Hz) use solid conductors; switching power supplies (100 kHz+) require Litz wire or foil conductors. Audio frequencies (20 Hz-20 kHz) have negligible skin effect in typical wire gauges but measurable effect in large power cables.

References

Microwave Engineering, 4th ed. · Classical Electrodynamics, 3rd ed.
  1. Microwave Engineering, 4th ed. — David M. Pozar (2011), Chapter 1.6 — Skin depth and surface resistance
  2. Classical Electrodynamics, 3rd ed. — John D. Jackson (1999), Chapter 5 — Skin effect in conductors

Shop Components

As an Amazon Associate we earn from qualifying purchases.

  • SMA ConnectorsStandard SMA RF connectors for board-to-cable connectionsAmazon →
  • RF Coaxial CablesCoaxial cable assemblies for RF signal routingAmazon →
  • TinySA Spectrum AnalyzerCompact handheld spectrum analyzer for RF measurement up to 960 MHzAmazon →